Vaisala Antenna-mounted Receiver AMR

Overview

Dual-polarization weather radars have superseded single-polarization radars as the standard for modern systems due to their precise rainfall measurement capacity. But upgrading old single-polarization radars has been an expensive and time-consuming project - until now. Vaisala's new antenna-mounted receivers have changed all that. The antenna-mounted receivers can be up and running in less than two weeks. Upgrading, rather than a carrying out a full replacement means:

  • A lower initial investment than a full radar replacement
  • Online calibration and maintenance reduces the need for site visits and associated costs
  • Onsite maintenance, when needed, is much quicker due to easy accessibility of components
Technical Specifications
System Specifications
Dual polarization receiverSTAR and LDR
CalibrationBuilt in automatic and remote calibration
Supported transmitter technology Designed for magnetron systems
Physical and Environmental Specifications
UNITS INSTALLED INSIDE RADOME
Ingress protection ratingIP54
Operating temperature range-40°C to +55 °C
Storage temperature range-50°C to +60 °C
Humidityup to 100%
Pressure700...1100 hPa
ANTENNA MOUNTED RECEIVER UNIT
Physical dimensions (w x h x d)800 x 564 x 367 mm
Weight36.5 kg
Temperature stabilizationThermoelectric
VibrationSensitive parts vibration isolated
WAVEGUIDE MATRIX
Physical dimensions (w x h x d)816 x 542 x 259 mm
Weight16 kg
POWER SUPPLY UNIT
Physical dimensions (w x h x d)331 x 386 x 201 mm
Weight12 kg
UNITS INSTALLED IN EQUIPMENT ROOM
Ingress protection ratingIP54
Operating temperature range-25 °C to +40 °C
Storage temperature range-50 °C to +60 °C
Humidityup to 100%
POWER RESET UNIT
Physical dimensions (w x h x d)235 x 600 x 200 mm
Weight15 kg
Operating voltages and Power consumption
RECEIVER UNIT, WAVEGUIDE MATRIX, POWER SUPPLY UNIT AND POWER RESET UNIT
Input voltage100-240 VAC, 50-60 Hz
Power consumption750 W (max), 500 W (typical)
RADAR SERVER COMPUTER
Input voltage100-240 VAC, 50-60 Hz
Power consumption1050 W (max), 200 W (typical)
Interfaces
Data connectionEthernet interface min. 1 Mbit/s
Transmitter triggerdefault 5 V, 50 ohm, surge protected
Remote resetGSM quad band
850/900/1800/1900, SMS control
Radar control interfaceVaisala RCP8 interfaces and IO62 panel
Waveguide matrix
Waveguide typeWR187
Operating frequency range5.5...5.7 GHz
Peak powermax 300 kW
Average powermax 600 W
Duty cyclemax 0.12%
Pulse widthmax 3.0 µs
PRFmax 2400 Hz
VSWR< 1.2
RF-to-IF Receiver
TypeDual stage, dual channel IF down converter
Dynamic range> 99 dB (2 µs pulse)
IF frequency442/60 MHz
Image rejection>80 dB
Tuning range5.5...5.7 GHz
Noise figure< 2 dB
Digital Receiver and Signal Processor
Signal processor typeVAISALA RVP900
IF digitizing16 bits, 100 MHz in 5 channels
Range resolutionN*15 m
Number of range binsUp to 4200
Maximum Range1024 km
Processing ModesPPP, FFT/DFT, Random Phase
2nd trip filtering/recovery
Data Outputs (8 and 16 bit)Zh, Zv, Zhv, V, W, SQI, ZDR, LDR, RHOHV, PHIDP, and KDP
Optional Data OutputsHCLASS, I/Q
High Sensitivity STAR mode Processing>3dB improvement in detectability
Azimuth Averaging2 to 1024 Pulses
Velocity de-aliasingDual PRF Velocity de-aliasing
2:3, 3:4, or 4:5 for 2X, 3X or 4X de-aliasing
Range de-aliasingRandom phase
Clutter filtersIIR, Fixed and Adaptive Width or GMAP >50 dB clutter cancellation
Radar Controller
TypeVAISALA RCP8 with IRIS/Radar
Scan modesPPI, RHI, Volume, Sector, Manual
Local displayReal time, ascope, BITE, products
Radar control interfaceRCP8 interfaces
Options
Optional wide dynamic range receiver>115 dB

Get Vaisala Antenna-mounted receiver AMR brochure in English

Life is not a problem to be solved, but a reality to be experienced.