TitanEA

Summary

The TitanEA is a strong motion Ethernet accelerograph specifically designed for networked deployments on (or in) large civil structures such as nuclear reactors, multi-story buildings, bridges and hydro-electric dams.

The TitanEA features the Class “A” Titan triaxial force balance sensor and its industry-leading dynamic range meets or exceeds the performance requirements of any local regulations for sensor specification.

It uses Precision Time Protocol or PTP Timing, which provides timing accuracy of .001ms to all sensors within an array, without the need for individual GPS connectivity at hard-to-reach sensor locations.

Also unique to the TitanEA is the single CAT5 Ethernet connection providing power, timing and data streaming capability. This provides maximum flexibility for sensor placement within a structure, costs less and is easier to install compared to the analogue cables required of less sophisticated instrumentation.

Event statistics (PGA, PGV, PGD, Sa) for each TitanEA and all TitanEAs within an array are accessible with any web-enabled device via the easily accessible events page resident within the GUI of each individual accelerograph, eliminating the need for a central computer within an array.

Nanometrics’ TitanEA might be right for you if:

  • You’re installing networked deployments on (or in) a large civil structure
  • You want to minimize back-up power requirements and overall deployment costs
  • You don’t want to deal with expensive and cumbersome analogue cables
  • You need event statistics to be accessible on any web-enabled device
Specifications

Specifications are subject to change without notice.

DIGITIZER PERFORMANCE
Channels 3 internal X,Y, Z axes
Sampling Simultaneous
Type 24 bit successive approximations
Digital Filter 140 db attenuation at output Nyquist
Filter Type Linear phase (contact us for other options)
Dynamic Range >138 db @ 100sps (max sine wave above shorted input)
Sample Rates 10,20,40,50,80,100,200,250,500,1000 sps
Dual Sample Rate Decimate primary rate by factor 2,5,10,20,50,100,200,250
Sensitivity 2,4,8,16,32, and 64 digitizer counts per ug +/-1%
CALIBRATION
Digital Calibration Playback standard .wav audio file editors
Step, 1Hz sine, PRB files pre-loaded
User installed custom waveforms
EVENTS
Type Bandpassed STA/LTA or threshold
Trigger Selection Independent threshold or STA/LTA ratio for each channel
STA/LTA Trigger Configurable STA,LTA,LTA Latching, trigger, and de-trigger thresholds
Trigger Votes User set votes assigned by channel, transmitted via IP multicast
Threshold Trigger Selectable from 0.01% to 100% of full scale
Event Statistics Peak ground acceleration, Velocity, Displacement,  Sa (0.3, 1, 3 Hz)
COMMUNICATIONS
Interfaces 10/100 Base-T Ethernet
IP Addressing Fixed IP or DHCP
Protocols UDP/IP (unicast/multicast), HTTP-based (inbound or outbound) streaming
Status LEDS Power, Ethernet, Timing, Overall Status and Event Notification
POWER
Type 48 VDC Power-over-Ethernet
<3W quiescent
TITAN EA SPECIFICATIONS
Timing Type PTP Timing 
Data Retrieval Direct download via Ethernet
Connectors Mil-circular CAT5 Ethernet
-Data
-Power-over-ethernet (48VDC)
-PTP Timing
Recording High Capacity internal CompactFlash (CF)
The secret of our success is we are all working together.