Trillium 360 Vault

Summary

Our new line of Trillium 360's give you full bandwidth coverage for global seismology and teleseismic monitoring with a single instrument.

Why the Trillium 360 Vault?

  • Very broadband, exceptional performance that meets GSN operational requirements
  • Extended low frequency range useful out to beyond a 10 000-second time period
  • Able to resolve below Peterson's new low-noise model (NLNM) down to a 300-second time period
  • Wide dynamic range with a clip level of +/-18.2 mm/s up to 10 Hz and 0.17 g above 10 Hz
  • Integrated bubble level, adjustable locking leveling feet
  • Automatic motorized re-centering, can be remotely initiated
Specifications

Specifications are subject to change without notice.

TECHNOLOGY
Topology Symmetric triaxial
Feedback Force balance with capacitive transducer
Leveling Integrated bubble level, adjustable locking levelling feet
Mass centering Automatic motorized re-centering, can be remotely initiated
Alignment Vertical scribe marks for E/W, precision holes for 5/16" alignment rod for N/S
PERFORMANCE
Self-noise Below the NLNM from 300 s to 10Hz (see Performance tab)
Sensitivity 1100 V-s/m ±0.5% precision
Bandwidth -3 dB points at 373 s and 155 Hz
Clip level 18.2 mm/s up to 10 Hz and 0.17 g above 10 Hz
Transfer function Lower corner poles within ±0.5% of nominal provided / 
High-frequency response within ±1 dB of nominal up to 50 Hz
Temperature ±10°C without recentering
Magnetic sensitivity <0.03 (m/s2)/T
INTERFACE
Velocity output 40 V peak-to-peak  
Selectable XYZ or UVW mode

Mass position output Three independent voltage outputs
Calibration input Single voltage input for all channels, independent calibration enabled for each channel  
Calibration in XYZ or UVW
Control lines Mass Center, Calibration Enable, XYZ/UVW mode
Connector 19-pin MIL-C-26482, mounted on base
Serial port RS-232 compatible serial IP (SLIP)  
Onboard web server standard HTTP  
For enhanced instrument control and status: mass centering, UWV/XYZ model, short/long period mode, firmware updates, temperature, mass position, instrument status, serial number and factory info
POWER
Supply voltage 9 to 36 Volts DC isolated input
Protection Reverse-voltage protected  
Auto-resettable over-current protection (No fuse to replace)
Power consumption 800 mW typical at 15V input
PHYSICAL
Case design Powder-coated aluminum pressure vessel
Diameter 25 cm
Height 26.5 cm without levelling feet  
29.0 ±0.5 cm depending on levelling feet extension
Weight 14 kg
Parasitic resonances None below 150 Hz
ENVIRONMENTAL
Operating temperature -20ºC to 60ºC (ultra-low temperature option available, please contact Nanometrics)
Storage temperature -40ºC to 70ºC
Shock 20 g half sine, 5 ms without damage, 6 axes  
No mass lock required for transport
Water immersion Rated to IP68 and NEMA 6P for outdoor use
Insulating cover Optional insulating cover available for quick and convenient installation
Performance
Life is not a problem to be solved, but a reality to be experienced.