Home / Products / Seismology / Trillium 360 Vault
Trillium 360 Vault
Summary
Our new line of Trillium 360's give you full bandwidth coverage for global seismology and teleseismic monitoring with a single instrument.
Why the Trillium 360 Vault?
- Very broadband, exceptional performance that meets GSN operational requirements
- Extended low frequency range useful out to beyond a 10 000-second time period
- Able to resolve below Peterson's new low-noise model (NLNM) down to a 300-second time period
- Wide dynamic range with a clip level of +/-18.2 mm/s up to 10 Hz and 0.17 g above 10 Hz
- Integrated bubble level, adjustable locking leveling feet
- Automatic motorized re-centering, can be remotely initiated
Specifications
Specifications are subject to change without notice.
TECHNOLOGY |
|
Topology | Symmetric triaxial |
Feedback | Force balance with capacitive transducer |
Leveling | Integrated bubble level, adjustable locking levelling feet |
Mass centering | Automatic motorized re-centering, can be remotely initiated |
Alignment | Vertical scribe marks for E/W, precision holes for 5/16" alignment rod for N/S |
PERFORMANCE |
|
Self-noise | Below the NLNM from 300 s to 10Hz (see Performance tab) |
Sensitivity | 1100 V-s/m ±0.5% precision |
Bandwidth | -3 dB points at 373 s and 155 Hz |
Clip level | 18.2 mm/s up to 10 Hz and 0.17 g above 10 Hz |
Transfer function | Lower corner poles within ±0.5% of nominal provided /
High-frequency response within ±1 dB of nominal up to 50 Hz |
Temperature | ±10°C without recentering |
Magnetic sensitivity | <0.03 (m/s2)/T |
INTERFACE |
|
Velocity output | 40 V peak-to-peak
Selectable XYZ or UVW mode |
Mass position output | Three independent voltage outputs |
Calibration input | Single voltage input for all channels, independent calibration enabled for each channel
Calibration in XYZ or UVW |
Control lines | Mass Center, Calibration Enable, XYZ/UVW mode |
Connector | 19-pin MIL-C-26482, mounted on base |
Serial port | RS-232 compatible serial IP (SLIP)
Onboard web server standard HTTP For enhanced instrument control and status: mass centering, UWV/XYZ model, short/long period mode, firmware updates, temperature, mass position, instrument status, serial number and factory info |
POWER |
|
Supply voltage | 9 to 36 Volts DC isolated input |
Protection | Reverse-voltage protected
Auto-resettable over-current protection (No fuse to replace) |
Power consumption | 800 mW typical at 15V input |
PHYSICAL |
|
Case design | Powder-coated aluminum pressure vessel |
Diameter | 25 cm |
Height | 26.5 cm without levelling feet
29.0 ±0.5 cm depending on levelling feet extension |
Weight | 14 kg |
Parasitic resonances | None below 150 Hz |
ENVIRONMENTAL |
|
Operating temperature | -20ºC to 60ºC (ultra-low temperature option available, please contact Nanometrics) |
Storage temperature | -40ºC to 70ºC |
Shock | 20 g half sine, 5 ms without damage, 6 axes
No mass lock required for transport |
Water immersion | Rated to IP68 and NEMA 6P for outdoor use |
Insulating cover | Optional insulating cover available for quick and convenient installation |
Performance
Life is not a problem to be solved, but a reality to be experienced.